# SDR R61A20100557

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 5, 2010
- Submitted: December 5, 2010
- Operation: Air carrier
- Aircraft: N801MA
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000012
- Aircraft time: 17,010 hours, 12,583 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Drain Mast
- Part number: 17098092403
- Condition: Corroded
- Location: Zone 100
- Part time: 17,010 hours, 12,583 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20100557

## Discrepancy

WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE DRAIN MAST SCREW HOLES ON PANEL 195NL.  MAINTENANCE REMOVED AND REPLACED THE DRAIN MAST ON PANEL 195NL IAW EMB 170 AMM 20-10-01.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.