# SDR R61A20110032

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 10, 2011
- Submitted: February 10, 2011
- Operation: Air carrier
- Aircraft: [N805MD](https://openairdocs.org/aircraft/N805MD), registered now
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000018
- Aircraft time: 17,235 hours, 12,847 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Gusset
- Part number: 17060257001
- Condition: Corroded
- Location: Fuselage
- Part time: 17,235 hours, 12,847 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20110032

## Discrepancy

WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON GUSSET AT RT FLOOR SUPPORT AT FRAME 89.  MAINTENANCE REMOVED AND REPLACED GUSSET ON RT FLOOR SUPPORT AT FRAME 89 IAW EMB 170 SRM 51-41-02 & EMBRAER IC 2009-170/00325.  MATERIAL USED 7475-T761 .040  PO 318207, P/N 170-60257-001 FOR REFERENCE.  A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.