# SDR R61A201202120092

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 12, 2012
- Submitted: February 13, 2012
- Operation: Air carrier
- Aircraft: N166HQ
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft serial: 19000166
- Aircraft time: 10,493 hours, 6,764 cycles
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Bolt
- Part number: NAS660310
- Condition: Corroded
- Location: L2 Door
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201202120092

## Discrepancy

WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE L2 DOOR AFT EMERGENCY EVACUATION SLIDE FITTING ATTACH HARDWARE CORRODED.  MAINTENANCE REMOVED AND REPLACED THE CORRODED BOLT, HARDWARE ON L2 DOOR AFT SLIDE FITTING IAW 190 AMM 53-23-21.  THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.