# SDR R61A201209070476

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 7, 2012
- Submitted: September 10, 2012
- Operation: Air carrier
- Aircraft: N176HQ
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft serial: 19000461
- Aircraft time: 2,403 hours, 1,483 cycles
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Gust Lock
- Condition: Out Of Adjust
- Location: L1 Door
- Stage of operation: TX
- How discovered: O
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201209070476

## Discrepancy

CREW REPORTED THE L1 DOOR GUST LOCK HAD SOME INTERFERENCE AND WAS HARD TO LOCK INTO PLACE.  MAINTENANCE ADJUSTED THE GUST LOCK LINKAGE PER EMB AMM AND OPS CHECKED GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.