# SDR R61A201311121145

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 12, 2013
- Submitted: November 13, 2013
- Operation: Air carrier
- Aircraft: N333NG
- Make and model: Bombdr DHC8402
- Aircraft serial: 4333
- Aircraft time: 5,563 hours, 5,325 cycles
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Filter
- Condition: Contaminated
- Location: Zone 800
- Stage of operation: CR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201311121145

## Discrepancy

CREW REPORTED THAT THE L1 DOOR SEAL LEAK AT 4.5 DP AND ABOVE AND IT SEEMED TO BE CYCLING BETWEEN SEALED AND UNSEALED. THE CABIN HELD PRESSURE AND AN EMERGENCY WAS NOT DECLARED.  MAINTENANCE INSPECTED THE DOOR SEAL IAW AMM WITH NO DEFECTS NOTED.  MAINTENANCE INSPECTED THE DESSICANT FILTER AND FOUND IT CONTAMINATED. MAINTENANCE R & R THE FILTER IAW AMM, PERFORMED OPS CHECK OF THE DOOR AND SEAL AND PRESSURIZED ACFT.  OPS CHECKED GOOD AND ACFT IS GOOD FOR SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.