# SDR R61A201505070311

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 7, 2015
- Submitted: May 25, 2015
- Operation: Air carrier
- Aircraft: [N111HQ](https://openairdocs.org/aircraft/N111HQ), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000173
- Aircraft time: 21,189 hours, 16,709 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Threshold
- Condition: Corroded
- Location: L2 Doorway
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201505070311

## Discrepancy

DURING HEAVY CHECK, L2 DOOR THRESHOLD AROUND GIRT BAR RIVETS IS CORRODED.  MAINTENANCE R & R L2 DOOR THRESHOLD BEAM IAW SRM 51-21-01, 51-43-03, 51-43-04, PN 170-65703-005. BEAM ACFT REMAINS UNTIL HEAVY CHECK IS COMPLETED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.