# SDR R61A201506170416

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 17, 2015
- Submitted: July 8, 2015
- Operation: Air carrier
- Aircraft: N809MD
- Make and model: Emb ERJ 170-100SU
- Registry model: [EMB ERJ 170-100SU](https://openairdocs.org/model/embraer-erj-170-100su) (OpenAirDocs)
- Aircraft serial: 17000022
- Aircraft time: 28,159 hours, 21,089 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Shear Plate
- Part number: 17065928001
- Condition: Corroded
- Location: Frames 87-88
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201506170416

## Discrepancy

DURING HEAVY CHECK, IT WAS REPORTED THAT CENTER AFT FUSELAGE SHEAR PANEL BETWEEN FRAMES 87-88 IS CORRODED.  MAINTENANCE R & R CENTER AFT FUSELAGE SHEAR PANEL BETWEEN FRAMES 87-88 IAW SRM 51-40-02, 51-42-01, 51-23-05, 51-23-06.  PN 170-65928-001, PANEL SHEAR.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.