# SDR R61A201706300478

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 30, 2017
- Submitted: July 5, 2017
- Operation: Air carrier
- Aircraft: [N865RW](https://openairdocs.org/aircraft/N865RW), registered now
- Make and model: Emb ERJ 170-100 SE
- Registry model: [EMB ERJ 170-100 SE](https://openairdocs.org/model/embraer-erj-170-100-se) (OpenAirDocs)
- Aircraft serial: 17000122
- Aircraft time: 32,331 hours, 19,508 cycles
- System (JASC): [2450 · AC Power Distribution System](https://openairdocs.org/jasc/2450)
- Part: Power Supply
- Part number: 59130165
- Part serial: C4042
- Condition: Burned
- Location: Zone 100
- Stage of operation: CR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201706300478

## Discrepancy

SPDA FAIL MESSAGE, PACK 1 AND 2 MESSAGE, FLAP LOW RATE MESSAGE, BLEED 1 FAIL MESSAGE, RECEIVED AN ELECTRICAL SMOKE ODOR IN THE COCKPIT AND CABIN. DIVERTED. R & R SPDA NR 2 POWER SUPPLY MODULE IAW AMM 24-61-11.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.