# SDR R61A20181228256

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 26, 2018
- Submitted: December 28, 2018
- Operation: Air carrier
- Aircraft: [N857RW](https://openairdocs.org/aircraft/N857RW), registered now
- Make and model: Emb ERJ 170-100 SE
- Registry model: [EMB ERJ 170-100 SE](https://openairdocs.org/model/embraer-erj-170-100-se) (OpenAirDocs)
- Aircraft serial: 17000079
- Aircraft time: 38,374 hours, 22,783 cycles
- System (JASC): [2133 · Pressure Regulator/Outflow Valve](https://openairdocs.org/jasc/2133)
- Part: Outflow Valve
- Part number: 2142501
- Part serial: 0482714
- Condition: Inoperative
- Location: Cabin Pressure
- Part time: 38,374 hours, 22,783 cycles
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A20181228256

## Discrepancy

CABIN ALTITUDE HIGH. DECLARED EMERGENCY, DIVERTED TO SDF, LANDED WITHOUT INCIDENT. R&R OUTFLOW VALVE IAW AMM 21-31-00, NO LEAKS NOTED. FOUND DUCT FROM GROUND CONNECTION TO AIRFRAME OFF, REATTACHED. LEAK CHECK GOOD.

---