# SDR R61A201903180316

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 18, 2019
- Submitted: March 30, 2019
- Operation: Air carrier
- Aircraft: N651RW
- Make and model: Emb ERJ 170-100 SE
- Registry model: [EMB ERJ 170-100 SE](https://openairdocs.org/model/embraer-erj-170-100-se) (OpenAirDocs)
- Aircraft serial: 17000072
- Aircraft time: 38,806 hours, 23,917 cycles
- System (JASC): [5313 · Fuselage Main, Longeron/Stringer](https://openairdocs.org/jasc/5313)
- Part: Stringer Splice
- Part number: 17005427004
- Condition: Cracked
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201903180316

## Discrepancy

***WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK*** PASSENGER CABIN, CFII/CFIII CRACKED FOUND ON STRINGER SPLICE AT FR 59 AND STR 10R. PASSENGER CABIN, CFII/CFIII CRACKED FOUND ON STRINGER SPLICE AT FR 59 AND STR 10R REMOVED AND REPLACED IAW SRM 51-43-03 PSE: 53-22-002.  A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.