# SDR R61A201904220400

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 22, 2019
- Submitted: April 22, 2019
- Operation: Air carrier
- Aircraft: N446YX
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000457
- Aircraft time: 11,162 hours, 7,546 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Splice
- Part number: 17060257001
- Condition: Corroded
- Location: Frame 90
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201904220400

## Discrepancy

DURING HEAVY CHECK VISIT FOUND CORROSION ON AFT WET AREA FLOOR SPLICE AT FR90 Y= +10.748. REMOVED AND REPLACED AFT WET AREA FLOOR SPLICE AT FR90 Y= +10.748.  RESTORED SURFACE PROTECTION REF. EMB SRM 51-23-05, 51-23-06. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
