## Discrepancy

DURING HEAVY CHECK VISIT FOUND CORROSION ON AFT WET AREA FLOOR SPLICE AT FR89 Y=+10.748. REMOVED AND REPLACED SPLICE AT AFT WET AREA FR89 REF. SRM 51-40-08.RESTORED SURFACE PROTECTION REF. EMB SRM 51-23-06. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.