# SDR R61A201912211420

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 13, 2019
- Submitted: December 21, 2019
- Operation: Air carrier
- Aircraft: [N403YX](https://openairdocs.org/aircraft/N403YX), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000365
- Aircraft time: 17,130 hours, 11,475 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Part number: 17013238001
- Condition: Cracked
- Location: Frame 12
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A201912211420

## Discrepancy

***WHILE A/C WAS OUT OF SERVICE FOR A HEAVY CHECK*** AT FR12 & LBL39 COCKPIT FLOOR STRUCTURE ANGLE FOUND CRACKED. REMOVED AND REPLACED ANGLE IAW SRM 51-41-01. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.