# SDR R61A2020121500868

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 26, 2020
- Submitted: December 15, 2020
- Operation: Air carrier
- Aircraft: N806MD
- Make and model: Emb ERJ 170-100 LR
- Registry model: [EMB ERJ 170-100 LR](https://openairdocs.org/model/embraer-erj-170-100-lr) (OpenAirDocs)
- Aircraft serial: 17000019
- Aircraft time: 35,807 hours, 27,130 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Splice
- Part number: 17065644001
- Condition: Corroded
- Location: Frames 87-89
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A2020121500868

## Discrepancy

WHILE IN HEAVY CHECK CORROSION WAS FOUND ON LT FLOOR SPLICE BETWEEN FRAME 87 AND 89.  AAR REPLACED THE SPLICE ON NRC 4500812-1000-0054, PER SRM 51-42-02.  THIS AIRCRAFT HAS BEEN RETURNED TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.