# SDR R61A202101140032

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 28, 2020
- Submitted: January 14, 2021
- Operation: Air carrier
- Aircraft: N646RW
- Make and model: Emb ERJ 170-100 SE
- Registry model: [EMB ERJ 170-100 SE](https://openairdocs.org/model/embraer-erj-170-100-se) (OpenAirDocs)
- Aircraft serial: 17000066
- Aircraft time: 43,802 hours, 27,203 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Part number: 17065669003
- Condition: Corroded
- Location: Zone 200
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A202101140032

## Discrepancy

DURING HEAVY CHECK MAINTENANCE FOUND RT FLOOR BEAM BETWEEN FR 86-89 HAS CORROSION.  CORRODED RT FLOOR BEAM BETWEEN FR 86-89 REMOVED AND REPLACED, IAW EMB 170 SRM 51-42-01 AND 51-43-01.  A/C REMAINS IN CHECK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.