# SDR R61A202101140044

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 28, 2020
- Submitted: January 14, 2021
- Operation: Air carrier
- Aircraft: N646RW
- Make and model: Emb ERJ 170-100 SE
- Registry model: [EMB ERJ 170-100 SE](https://openairdocs.org/model/embraer-erj-170-100-se) (OpenAirDocs)
- Aircraft serial: 17000066
- Aircraft time: 43,802 hours, 27,203 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Shear Panel
- Part number: 17065917007
- Condition: Corroded
- Location: Zone 100
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A202101140044

## Discrepancy

WHILE AC WAS IN FOR HEAVY CHECK, FOUND CENTER FUSELAGE 3 FLOOR STRUCTURE CENTER SHEAR PANEL AT FR 86 HAS CORROSION.  AAR MX REPLACED SHEAR PANEL PN 170-65917-007, IAW SRM 51-42-01.  SEE AAR NRC 4500833-1000-0026 FOR WORK PERFORMED.  AC REMAINS IN YQG FOR COMPLETION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.