# SDR R61A2021020700141

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 23, 2021
- Submitted: February 7, 2021
- Operation: Air carrier
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000510
- Aircraft time: 13,637 hours, 8,888 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Shear Panel
- Part number: 17091919001
- Condition: Corroded
- Location: Zone 100
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A2021020700141

## Discrepancy

DURING HEAVY CHECK MAINTENANCE FOUND CFIII FLOOR STRUCTURE RH SHEAR PANEL BETWEEN FR87-FR88 HAS CORROSION. CFIII FLOOR STRUCTURE RH SHEAR PANEL BETWEEN FR87-88 REPLACED WITH NEW IAW SRM 51-42-01. A/C REMAINS IN CHECK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.