# SDR R61A2026031200059

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 12, 2026
- Submitted: March 16, 2026
- Operation: Air carrier
- Aircraft: [N747YX](https://openairdocs.org/aircraft/N747YX), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000676
- Aircraft time: 19,432 hours, 13,870 cycles
- System (JASC): [2900 · Hydraulic Power System](https://openairdocs.org/jasc/2900)
- Part: Warning Message
- Condition: False Activation
- Location: Hyd Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A2026031200059

## Discrepancy

HYD 2 LO PRESS DURING CRUISE. MESSAGE EXTINGUISHER AFTER 5-10 SECONDS. QTY 50% PRESS IS AMBER DASHES. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. RESET CB CBP. PERFORMED OPS CHECK OF HYD PRESS INDICATION. OPS CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.