# SDR R61A2026052300143

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 23, 2026
- Submitted: May 27, 2026
- Operation: Air carrier
- Aircraft: [N879RW](https://openairdocs.org/aircraft/N879RW), registered now
- Make and model: Emb ERJ 170-100 LR
- Registry model: [EMB ERJ 170-100 LR](https://openairdocs.org/model/embraer-erj-170-100-lr) (OpenAirDocs)
- Aircraft serial: 17000227
- Aircraft time: 38,034 hours, 28,611 cycles
- System (JASC): [3010 · Airfoil Anti/De-ice System](https://openairdocs.org/jasc/3010)
- Part: Sensor
- Condition: Faulted
- Location: Zone 500
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A2026052300143

## Discrepancy

ANTI-ICE WING 1 LEAK EICAS MSG. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. REMOVED AND REPLACED LH WING SLAT #2 WING ANTI-ICE BACKWALL TEMP SENSOR AND W511 HARNESS.

---