# SDR R61A2026082400245

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 21, 2026
- Submitted: August 25, 2026
- Operation: Air carrier
- Aircraft: [N420YX](https://openairdocs.org/aircraft/N420YX), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000385
- Aircraft time: 31,308 hours, 21,686 cycles
- Engine: Ge CF348E5
- System (JASC): [7300 · Engine Fuel and Control](https://openairdocs.org/jasc/7300)
- Part: Pressure Switch
- Part number: 1103P111401
- Part serial: 0707
- Condition: Faulted
- Location: Nr 2 Engine
- Part time: 5,494 hours, 4,368 cycles
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A2026082400245

## Discrepancy

ENG 2 LOW FUEL PRESSURE INFLIGHT, CREW PERFORMED QRH PROCEDURES AND DIVERTED TO BOS, EMERGENCY DECLARED AND LANDED SAFELY, FUEL LOW PRESSURE SWITCH FROM E2 SWAPPED WITH E1, OPS CHECK FAILED FURTHER TROUBLESHOOTING REQUIRED PLACED ON MEL 73-31-01-1.  REMOVED AND REPLACED (E1) FUEL LOW PRESSURE SWITCH, OPS CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.