# SDR R61A2026091100258

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 11, 2026
- Submitted: September 15, 2026
- Operation: Air carrier
- Aircraft: [N228JQ](https://openairdocs.org/aircraft/N228JQ), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000218
- Aircraft time: 44,313 hours, 29,108 cycles
- System (JASC): [2897 · Fuel System Wiring](https://openairdocs.org/jasc/2897)
- Part: Wire Harness
- Condition: Faulted
- Location: Fuel Cell
- Stage of operation: CL
- How discovered: V
- Nature of condition: N
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/R61A2026091100258

## Discrepancy

FUEL IMBALANCE ON CLIMB OUT, APPROXIMATELY 23000 FEET. THE NUMBER 1 TANK WAS DROPPING 10-20LB PER SECOND IN FUEL. WE THOUGHT WE HAD A POSSIBLE FUEL LEAK, HOWEVER LEFT FUEL TANK STABILIZED AT 3800LB AND RIGHT TANK AT 3600LB. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R LH FUEL TANK HARNESS ASSEMBLY.

---