# SDR RAIA201312050002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 5, 2013
- Submitted: December 16, 2013
- Operation: Air carrier
- Aircraft: N811HK
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145256
- Aircraft time: 32,108 hours, 27,999 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Thermal Switch
- Condition: Inoperative
- Location: Nr 2 Bleed Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/RAIA201312050002

## Discrepancy

BLEED 2 LEAK DURING CRUISE, ACFT RETURNED.  MAINTENANCE INSPECTED AND R & R THERMAL SWITCH AT AIR STARTER INLET AND PERFORMED BLEED LEAK TEST.  NO DEFECTS NOTED AT THIS TIME.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.