# SDR RAIA201405140001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 14, 2014
- Submitted: May 16, 2014
- Operation: Air carrier
- Aircraft: N845HK
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 14500842
- Aircraft time: 24,302 hours, 22,554 cycles
- System (JASC): [2613 · Overheat Detection](https://openairdocs.org/jasc/2613)
- Part: Thermostat
- Condition: Malfunctioned
- Location: Bleed
- Stage of operation: CL
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/RAIA201405140001

## Discrepancy

BLEED NR 2 OVERTEMP ILLUMINATED DURING CLIMB OUT WITH BLEED 1 LEAK ON EICAS, ACFT RETURNED TO BLOCK.  MAINTENANCE INSPECTED, OPS CHECK BLEED LEAK AND OPS CHECK GOOD AND REPLACED THE NR 2 BLEED THERMOSTAT, OPS CHECKED GOOD.

---