- Page: https://openairdocs.org/sdr/RAIA201909020001

## Discrepancy

PAC #1 VALVE CLOSED IN FLIGHT.  FOUND DISCONNECTED COUPLING AT DUEL TEMP CONTROLLER.  RECONNECTED COUPLING AND PERFORMED OPS CHECK.  LEAK CHECK OF PACK 1 OPS CHECK GOOD AT THIS TIME.

---