# SDR REXA2012030300291

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 3, 2012
- Submitted: March 6, 2012
- Operation: Air carrier
- Aircraft: [N187PQ](https://openairdocs.org/aircraft/N187PQ), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 9187
- Aircraft time: 9,240 hours, 6,487 cycles
- System (JASC): [3620 · Pneumatic Indicating System](https://openairdocs.org/jasc/3620)
- Part: Warning System
- Condition: False Activation
- Location: Bleed Air Sys
- Stage of operation: IN
- How discovered: O
- Nature of condition: N
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/REXA2012030300291

## Discrepancy

LEFT ENG BLEED CAUTION MSG.  TROUBLESHOT TO MT29 VIA ECS SYSTEM TEMP/ PRESSURE CHECK.  REMOVED AND REPLACED MT29 OPS CHECK GOOD AT THIS TIME.  OK FOR SCV.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.