## Discrepancy

EN-ROUTE HYD 3 HI TEMP CAUTION POSTED, RAN NON-NORMAL CHECKLIST, SYS 3 PSI DROPPED TO 0 PRIOR TO LANDING.  TURNED 3A 3B ON IAW NON-NORMAL CHECKLIST & PSI BACK TO NORMAL.  R & R NR 3 HYD RESERVOIR IAW AMM 29-12-30.  OPERATIONS & LEAK CHECKED GOOD AT THIS TIME.  HYD PRESS & TEMP REMAINED ON NORMAL RANGE.  SEE NON-ROUTINE CARD 532062 FOR WORK PERFORMED. ACFT OF FOR SERVICE AT THIS TIME,  PN ON OFF 960450-1 SN OFF 807 SN ON 0028.

---