# SDR REXA2016062201133

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 22, 2016
- Submitted: June 24, 2016
- Operation: Air carrier
- Aircraft: [N905XJ](https://openairdocs.org/aircraft/N905XJ), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15137
- Aircraft time: 20,831 hours, 13,677 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Door Sill
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/REXA2016062201133

## Discrepancy

AFT CARGO DOOR FLOOR SILL IS CORRODED BETWEEN FS 1000 TO FS 1047 AND HAS MINOR CHAFING DAMAGE FROM STEP PLATE, CONTINUATION CARD 81513711, OP 205.  R & R CARGO DOOR SILL IAW SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-42-13-001-001-A01, 51-42-21-001-001-A01.  LEAK CHECK GOOD IAW AMM 52-00-00-790-801-A01.  ADJUSTMENT CHECK OF AFT CARGO DOOR AND OPS TEST GOOD IAW AMM'S 52-31-00-220-801-A01, 52-31-00-820-801-A03.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.