## Discrepancy

IN CRUISE, HYD QTY IND DROPPED TO STAND PIPE  COMPLYED WITH QRH PROCEDURES EM AIRBRAKE HANDLE WIRE BROKEN.  FOUND O-RING BETWEEN SLOT CONTROL VALVE AND C/H HYD MANIFOLD BLOWN.  REMOVED AND REPLACED SAME PER M/M 27-80-4.  SYSTEM OPS AND LEAK CHECKS GOOD

---