# SDR RRXA97210

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 22, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N602AL](https://openairdocs.org/aircraft/N602AL), registered now
- Make and model: Doug DC-8-73F
- Registry model: [Doug DC-8-73F](https://openairdocs.org/model/douglas-dc-8-73f) (OpenAirDocs)
- Aircraft serial: 45991
- System (JASC): [2612 · Fire Detection](https://openairdocs.org/jasc/2612)
- Part: Fire Loop
- Part number: 899096
- Condition: Malfunctioned
- Location: Nr 2 Engine
- Stage of operation: CR
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/RRXA97210

## Discrepancy

INTERMITTENT FIRE WARNING ON NR 2 ENGINE.  REMOVED AND REPLACED NR 2 ENGINE RT SIDE FAN COWL FIRE LOOP DETECTOR IAW DC-8 MM CHAPTER 26-10-1, OPERATIONAL CHECK GOOD.

---