# SDR RU3A20140603020

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 3, 2014
- Submitted: June 5, 2014
- Operation: Air carrier
- Aircraft: [N54](https://openairdocs.org/aircraft/N54), registered now
- Make and model: Lear 60LEAR
- Aircraft serial: 009
- Aircraft time: 7,785 hours, 3,687 cycles
- System (JASC): [2430 · DC Generating System](https://openairdocs.org/jasc/2430)
- Part: Controller
- Condition: Out Of Adjust
- Location: Electrical Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: H
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/RU3A20140603020

## Discrepancy

RIGHT GEN FAILED IN CRUISE FLIGHT AT 11,000'.  RESET GEN & IT OPERATED NORMALLY FOR ABOUT 7 MINS & IT FAILED AGAIN.  RESET GEN A SECOND TIME & REMAINED ON LINE FOR REMAINDER OF FLIGHT.  ADJUSTED LT & RT GEN CONTROL.  CLEANED & TORQUED GEN TERMINAL LEADS. OPERATIONAL CHECKOUT OF THE DC GENERATION SYS CHECKED GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.