# SDR SA04109

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 25, 2004
- Submitted: November 29, 2004
- Operation: Air carrier
- Aircraft: [N717UW](https://openairdocs.org/aircraft/N717UW), registered now
- Make and model: Airbus A319-112
- Registry model: [Airbus A319-112](https://openairdocs.org/model/airbus-industrie-a319-112) (OpenAirDocs)
- Aircraft serial: 1069
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Epsu
- Part number: 32145410
- Condition: Faulty
- Location: Emergency Lights
- Part time: 14,594 hours
- Stage of operation: IN
- How discovered: 9
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SA04109

## Discrepancy

PHL - THE EMERGENCY LIGHT SYSTEM FAILED TEST WITH MESSAGE,"EPSU UNIT EMER L".  MAINTENANCE REPLACED THE EMERGENCY POWER SUPPLY UNIT BELOW THE LEFT EMERGENCY OVERWING DOOR.  OPERATIONALLY TESTS OK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.