# SDR SCNA97053

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 27, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N151SY](https://openairdocs.org/aircraft/N151SY), registered now
- Make and model: Doug DC-10-15
- Registry model: [Doug DC-10-15](https://openairdocs.org/model/mcdonnell-douglas-dc-10-15) (OpenAirDocs)
- Aircraft serial: 48295
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Power Supply
- Part number: EMBS1392
- Condition: Inoperative
- Location: Cabin
- Stage of operation: IN
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SCNA97053

## Discrepancy

FORWARD OVERHEAD EMERGENCY LIGHT POWER SUPPLY FAILED SELF TEST.  REMOVED AND REPLACED POWER SUPPLY IN ACCORDANCE WITH 33-51-01 AND OPS CHECKED GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.