# SDR SCNA98027

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 5, 1998
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N572SC](https://openairdocs.org/aircraft/N572SC), registered now
- Make and model: Doug DC-10-10
- Registry model: [Doug DC-10-10](https://openairdocs.org/model/mcdonnell-douglas-dc-10-10) (OpenAirDocs)
- Aircraft serial: 46977
- System (JASC): [2170 · Humidity Control System](https://openairdocs.org/jasc/2170)
- Part: Coalescer Bag
- Condition: Contaminated
- Location: Nr 1 Pack
- Stage of operation: CL
- Nature of condition: B
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SCNA98027

## Discrepancy

WHILE WARMING THE COCKPIT TEMPERATURE ZONE TWO HAZY FOG POURED IN VENTS THROUGHOUT THE AIRCRAFT.   FOUND NUMBER ONE PACK WATER SEPARATOR DIFFERENTIAL PRESSURE INDICATOR POPPED.  RESET INDICATOR AND REPLACED WATER SEPARATOR BAG PER MAINTENANCE MANUAL CHAPTER 215100.

---