# SDR SIMA200128702

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 14, 2001
- Submitted: November 28, 2001
- Operation: Air carrier
- Aircraft: N605RR
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145059
- System (JASC): [2932 · Hydraulic Pressure Sensor](https://openairdocs.org/jasc/2932)
- Part: Pressure Switch
- Part number: 156221
- Part serial: 0058
- Condition: Leaking
- Location: Hydraulic Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: E
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA200128702

## Discrepancy

GRR - FLT 3795 - CREW REPORTED THE NR 2 HYDRAULIC LOST ALL FLUID, ENGINE AND ELECTRIC PUMP SHUTDOWN AND EMERGENCY WAS DECLARED.  MAINTENANCE FOUND THE NR 2 HYDRAULIC SYSTEM PRESSURE SWITCH TO BE LEAKING.  A NEW PRESSURE SWITCH WAS INSTALLED IAW EMB MM.  OPERATIONAL AND LEAK CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.  (M)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.