# SDR SIMA20140607006

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 7, 2014
- Submitted: June 12, 2014
- Operation: Air carrier
- Aircraft: [N606AE](https://openairdocs.org/aircraft/N606AE), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145062
- Aircraft time: 38,946 hours, 32,364 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Valve
- Part number: C1431236
- Part serial: 98111530
- Condition: Failed
- Location: Nr 2 A/C Pack
- Stage of operation: NR
- How discovered: O
- Nature of condition: J, B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20140607006

## Discrepancy

NR 2 A/C PACK OVERHEAT MESSAGE ON EICAS THAT WOULD NOT GO OUT, WITH A HOT OR BURNING ODOR.   R & R DUAL TEMP CONTROL VALVE IAW AMM 21-60-01.  OS CHECKED GOOD.  LEAK CHECKED GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.