# SDR SIMA20141002006

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 2, 2014
- Submitted: October 6, 2014
- Operation: Air carrier
- Aircraft: [N849AE](https://openairdocs.org/aircraft/N849AE), registered now
- Make and model: Emb EMB-135KL
- Registry model: [EMB EMB-135KL](https://openairdocs.org/model/embraer-emb-135kl) (OpenAirDocs)
- Aircraft serial: 145716
- Aircraft time: 27,870 hours, 25,096 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Valve
- Part number: 8166042
- Part serial: 200103444
- Condition: Failed
- Location: Nr 2 Pack
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20141002006

## Discrepancy

DURING CLIMB THROUGH 12,000 FEET, NR 2 PACK VALVE FAILED MESSAGE.  R & R NR 2 PACK VALVE IAW AMM 21-51-01.  OPS CHECKED GOOD.  LEAK CHECKED GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.