# SDR SIMA20150131001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 31, 2015
- Submitted: February 2, 2015
- Operation: Air carrier
- Aircraft: [N618AE](https://openairdocs.org/aircraft/N618AE), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145097
- Aircraft time: 37,626 hours, 34,351 cycles
- System (JASC): [3620 · Pneumatic Indicating System](https://openairdocs.org/jasc/3620)
- Part: Warning System
- Condition: False Activation
- Location: Cockpit
- Stage of operation: CL
- How discovered: O
- Nature of condition: N
- Precautionary procedure: B
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20150131001

## Discrepancy

NUMBER 1 BLEED LEAK ILLUMINATED ON CLIMB OUT ON EICAS & NR 1 ENG BLEED SWITCH.  SECURED NR 1 ENG BLEED SWITCH & ANNUNCIATION EXTINGUISHED, HAPPENED DURING CLIMB OUT JUST AFTER ANTI-ICE SYS TURNED OFF.  INSPECTED DUCTS & JOINTS IN THE NR 1 BLEED SYS IAW ETN-EM-36-048, NO LEAKS FOUND.  PERFORMED THE OPERATIONS TEST OF THE AIR BLEED SYS IAW AMM 36-00-00.  OPERATIONS CHECKED GOOD.  NO BLEED LEAK MSG.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.