# SDR SIMA20150625005

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 25, 2015
- Submitted: June 30, 2015
- Operation: Air carrier
- Aircraft: [N531EG](https://openairdocs.org/aircraft/N531EG), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10309
- Aircraft time: 12,893 hours, 8,553 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Line
- Condition: Leaking
- Location: Hyd System
- Stage of operation: CL
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20150625005

## Discrepancy

DURING CLIMB,  CREW RECEIVED A HYD SYS 1 LOW CAUTION MESSAGE.  COMPLIED WITH AOM VOL 1 PROCEDURES, DECLARED AN EMERGENCY & RETURNED WITHOUT INCIDENT.   R & R RT HYDRAULIC PRESSURE LINE IAW AMM 29-17-06.  LEAK CHECKED, NO LEAKS NOTED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.