# SDR SIMA20160817001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 17, 2016
- Submitted: August 18, 2016
- Operation: Air carrier
- Aircraft: [N691AE](https://openairdocs.org/aircraft/N691AE), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 14500860
- Aircraft time: 30,124 hours, 25,748 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Shutoff Valve
- Part number: 8166041
- Part serial: 200103406
- Condition: Failed
- Location: Nr 2 A/C Pack
- Stage of operation: CL
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20160817001

## Discrepancy

NR 2 A/C PACK CIRCUIT BREAKER TRIPPED DURING CLIMB OUT, AROUND 10000FT.  NR 2 VALVE PRESSURE REGULATOR AND SHUTOFF VALVES REPLACED IAW AMM 21-51-01 OPS CHECKED GOOD.

---