# SDR SIMA2018052117002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 17, 2018
- Submitted: May 21, 2018
- Operation: Air carrier
- Aircraft: [N678AE](https://openairdocs.org/aircraft/N678AE), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 14500813
- Aircraft time: 33,422 hours, 29,404 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Coupler
- Condition: Failed
- Location: Nr 1 A/C Pack
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA2018052117002

## Discrepancy

DURING CLIMB OUT, A BLEED 1 VALVE FAIL AND PACK 1 VALVE FAIL ILLUMINATED ON EICAS.  FOUND A BLOWN COUPLING ON THE NR 1 A/C PACK NEXT TO THE DUAL TEMP CONTROL VALVE.   R & R THE COUPLING, OPS AND LEAK CHECKED GOOD IAW  AMM 21-60-01, AND 21-50-00.

---