# SDR SIMA20190712001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 12, 2019
- Submitted: July 15, 2019
- Operation: Air carrier
- Aircraft: [N942LL](https://openairdocs.org/aircraft/N942LL), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 14500930
- Aircraft time: 35,167 hours, 29,740 cycles
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Wire
- Condition: Not Reported
- Location: Electrical Sys
- Stage of operation: UK
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20190712001

## Discrepancy

WHEN APU WAS STARTED ON THE GND BOTH PFDS WENT BLACK AND 115 VAC BUS OFF MESSAGE WAS DISPLAYED FOLLOWED BY A BURING SMELL "TRANSFERRED TO NRWC 942-ORD-04043". C/A-REMOVED AND REPLACED WIRE W126-0003-00 AND W126-0004-00 IAW AMM 24-65-00 AND SWPM 20-21-00. REMOVED AND REPLACED INTERCONNECTION BAR W1007 IAW AMM 24-60--01 AND SWPM 20-21-00. PERFORMED OPS TEST DC ELECTRICAL LOAD DISTRIBUTION SYSTEM IAW AMM 24-60-00, OPS TEST GOOD NO DEFECTS NOTED.

---