## Discrepancy

BLD 2 LEAK ON CLIMB OUT DECLARED EMERGENCY -C/A-SUSPECT BAD DUCT LEAK DETECTOR.PERFORMED CONTINUITY TEST FORM CONNECTOR J1020 PN A-6 TO GROUND IAW SWPM 20-20-03. CONTINUITY TEST GOOD PIN A-6 HAS NO CONTINUITY TO GROUND.

---