# SDR SIMA20210416003

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 16, 2021
- Submitted: April 19, 2021
- Operation: Air carrier
- Aircraft: [N616AE](https://openairdocs.org/aircraft/N616AE), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145092
- Aircraft time: 48,512 hours, 43,965 cycles
- System (JASC): [7500 · Engine Bleed Air System](https://openairdocs.org/jasc/7500)
- Part: Warning Message
- Condition: False Activation
- Location: Nr 1 Bleed Sys
- Stage of operation: CR
- How discovered: V
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20210416003

## Discrepancy

BLEED 1 LEAK EICAS MSG IN AIR. HAPPENED AFTER OR DIRECTLY AFTER ENTERING ICING DID NOT DECLARE EMERGENCY-C/A-PERFORMED DUCT LINE INSPECTION AND CHECK IAW EMB 145 36-11-09 AND PERFORMED ENGINE BLEED VALVE OPERATIONAL CHECK IAW 36-11-05. OPS CHECK GOOD

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.