# SDR SIMA20221025002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 25, 2022
- Submitted: October 27, 2022
- Operation: Air carrier
- Aircraft: [N616AE](https://openairdocs.org/aircraft/N616AE), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145092
- Aircraft time: 51,226 hours, 47,038 cycles
- System (JASC): [3620 · Pneumatic Indicating System](https://openairdocs.org/jasc/3620)
- Part: Clamp
- Condition: Unsecure
- Location: Nr 1 Bleed
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20221025002

## Discrepancy

A/I BACK TO ORD DUE TO BLEED 1 LEAK DURING FLIGHT. EMERGENCY WAS DECLARED BUT WAS NOT OVERWEIGHT. FLT CHG EQP AND CONTINUED-C/A-PERFORMED VISUAL AND LEAK INSPECTION OF DUCT AIR BLEED LINES OF SYSTEM 1 IAW EMB 145 AMM TASK 36-11-09. RE-TORQUED V-BAND CLAMPS AT JOINT 21 INSIDE LEFT PYLON.PERFORMED OPC CHECK IAW EMB-145 36-00-00. OPC GOOD. NO LEAKS OR FUTTHER DEFECTS NOTED.

---