# SDR SIMA20260614001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 14, 2026
- Submitted: June 15, 2026
- Operation: Air carrier
- Aircraft: [N787BP](https://openairdocs.org/aircraft/N787BP), registered now
- Make and model: Emb ERJ 170-100 LR
- Registry model: [EMB ERJ 170-100 LR](https://openairdocs.org/model/embraer-erj-170-100-lr) (OpenAirDocs)
- Aircraft serial: 17000046
- Aircraft time: 45,328 hours, 33,831 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Hydraulic Line
- Condition: Failed
- Location: Zone 100
- Stage of operation: NR
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20260614001

## Discrepancy

HYD SYS 2 SHOWING 0%. EMERGENCY DECLARED.   EMERGENCY DECLARED. R & R LT MLG FWD DOWNLOCK RELEASE ACTUATOR HYDRAULIC HOSE IAW AMM 29-10-13 OPS CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.