# SDR SIMA20260626001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 26, 2026
- Submitted: June 29, 2026
- Operation: Air carrier
- Aircraft: [N748RR](https://openairdocs.org/aircraft/N748RR), registered now
- Make and model: Emb ERJ 170-100 SE
- Registry model: [EMB ERJ 170-100 SE](https://openairdocs.org/model/embraer-erj-170-100-se) (OpenAirDocs)
- Aircraft serial: 17000072
- Aircraft time: 52,248 hours, 34,016 cycles
- System (JASC): [2722 · Rudder Actuator](https://openairdocs.org/jasc/2722)
- Part: Actuator
- Part number: 4154001009
- Condition: Leaking
- Location: Zone 300
- Stage of operation: CL
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20260626001

## Discrepancy

HYD LO QTY 3 RECEIVED IN FLIGHT. 18% INITIAL. DOWN TO 14% UPON LANDING. EMERGENCY VEHICLES SAW HYDRAULIC FLUID LEAKING AT A SIGNIFICANT RATE FROM THE TAIL SECTION OF THE AIRCRAFT. IT IS STILL DRIPPING WITH AIRCRAFT DE-ENERGIZED AND POWERED OFF. "TRANSFERRED TO NRWC 748-ORD-02154" (EMERGENCY DECLARED). SERVICE HYD ACCUMULATOR #3 IAW AMM12-15-05 REF NRWC 784-ORD-02156 RAR LOWER RUDDER PCU IAW AMM 27-22-01 OPS CHECK GOOD AND LEAK CHECK GOOD

---