# SDR SIMA20260627002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 27, 2026
- Submitted: June 29, 2026
- Operation: Air carrier
- Aircraft: [N318JE](https://openairdocs.org/aircraft/N318JE), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000968
- Aircraft time: 5,744 hours, 4,040 cycles
- System (JASC): [2930 · Hydraulic Indicating System](https://openairdocs.org/jasc/2930)
- Part: Indication Sys
- Condition: Faulted
- Location: Zone 100
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20260627002

## Discrepancy

HYD (2) LO PRESS [CAUTION] AND HYD (2) LO QTY ADVISORY RECEIVED IN FLIGHT. PRESS WAS 0 AND QTY SHOWED 0 WHEN EICAS MESSAGES RECEIVED. RAN QRH. DECLARED EMERGENCY AND DIVERTED TO KBIL AS PRECAUTION. PERFOMRED HYD LOW FIM TASK 29-11-00-810-806-A.  INSPECTED SERVICING HYD REVSERVOIR NR 2 IAW AMM 12-12-01. PERFROMED ADJ/TEST HYD 2 RESERVOIR QTY INDICATION IAW AMM 29-32-01. ALL INDICATION ON THE MFD IS THE SAME INDICATION AS THE HYD 2 RESERVOIR. NO MESS FOR HYD 2 LOW ON EICAS. NO DEFECT NOTED AT THIS TIME. FOUND TO BE TRANSITORY CONDITION. OKAY FOR SERVICE

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.