# SDR SIMA20260929001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 29, 2026
- Submitted: September 30, 2026
- Operation: Air carrier
- Aircraft: [N236NN](https://openairdocs.org/aircraft/N236NN), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000572
- Aircraft time: 26,429 hours, 17,859 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Controller
- Part number: 10012534
- Condition: Failed
- Location: Nr 2
- Stage of operation: CL
- How discovered: V
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SIMA20260929001

## Discrepancy

BLEED 2 OVER PRESSURE, QRH RAN DID NOT EXTINGUISH, BLEED SHOWED 114 PSI WITH BLEED 2 OFF RTF TO DFW.  DECLARED AN EMERGENCY.   R & R NR 2 TORQUE MOTOR CONTROLLER PER AMM 36-11-06, C/W BLEED 2 TM CONTROLLER IBIT CH 1 AND BLEED 2 TM CONTROLLER IBIT CH 2 IN REF TO AMM 45-45-00, TEST PASS AND NO FAULT NOTED AT THIS TIME. FCF FOUND SATISFACTORY.

---