# SDR SRAA970112

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 15, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N918SJ](https://openairdocs.org/aircraft/N918SJ), registered now
- Make and model: Lkheed 382G
- Aircraft serial: 4208
- System (JASC): [2160 · Cabin Temperature Control System](https://openairdocs.org/jasc/2160)
- Part: Temp Ctr Valve
- Part number: 2037201
- Condition: Inoperative
- Location: Cargo Compt
- Stage of operation: TX
- Nature of condition: J
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SRAA970112

## Discrepancy

CARGO COMPARTMENT OVERHEAT ILLUMINATED ON TAXI.  FOUND TEMPERATURE CONTROL VALVE INOPERABLE.  REPLACED VALVE AND OPERATIONAL CHECK GOOD PER IAW MM CH 21.

---