# SDR SWAA2021061671515

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 11, 2021
- Submitted: June 16, 2021
- Operation: Air carrier
- Aircraft: N732SW
- Make and model: Boeing 737-7H4
- Registry model: [Boeing 737-7H4](https://openairdocs.org/model/boeing-737-7h4) (OpenAirDocs)
- Aircraft serial: 27864
- Aircraft time: 74,727 hours, 43,976 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Support
- Condition: Corroded
- Location: Bs 727-807 Lbl21
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWAA2021061671515

## Discrepancy

CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS807 - BS727 LBL21 WL157. ; / INSTALLED NEW FLOOR TO SIDEWALL SUPPORT IN ACB BS 727-847 LBL21 WL157 IAW SRM 51-40-02 AND DWG #146A7500.;OK TO INSTALL NEW FLOOR TO SIDEWALL SUPPORT IN AFT CARGO BAY BS807-727 LBL21 WL157;OK TO INSTALL NEW FLOOR TO SIDEWALL SUPPORT IN AFT CARGO BAY BS807-727 LBL21 WL157.;REMOVED CORROSION ON L/H FLOOR TO SIDEWALL SUPPORT BS 727-807 LBL 21 WL 157 IN NUMEROUS 1'X1' AREAS; REMOVED 0.015 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. MICROMETER USED ID4566A S/N UNKNOWN;REMOVED OLD PART FROM PART ASSIGNED ROW;VERIFIED INSTALLED NEW FLOOR TO SIDEWALL SUPPORT IN ACB BS 727-847 LBL21 WL157 IAW SRM 51-40-02 AND DWG #146A7500.;VERIFIED VERIFIED INSTALLED NEW FLOOR TO SIDEWALL SUPPORT IN ACB BS 727-847 LBL21 WL157 IAW SRM 51-40-02 AND DWG #146A7500. <BR><BR>CARD COMPLETE;VERIFIED REMOVAL OF CORROSION ON L/H FLOOR TO SIDEWALL SUPPORT BS 727-807 LBL 21 WL 157 IN NUMEROUS 1'X1' AREAS; REMOVED 0.015 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. MICROMETER USED ID4566A S/N UNKNOWN;LOCATED AND DRILLED NEW ACB LH FLOOR TO SIDEWALL SUPPORT BS 727 TO BS847 IAW SRM 51-40-05-0G-0 SRM 51-40-02-0G-0;LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02; 51-40-05.;REMOVED ACB LH FLOOR TO SIDEWALL SUPPORT; BS 727 TO 847 PER SRM 51-40-02-0G-0

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.